Ki jan yo di si kouch asye galvanised bezwen antretyen oswa ranplasman?

Jun 17, 2025Kite yon mesaj

1. Ki diferan sitiyasyon karakteristik sifas kouch yo?

Nòmal kouch zenk: ajan-gri ekla metalik, pa gen okenn domaj evidan

Blan rouye (idwoksid zenk): poud blan oswa sibstans flokulan parèt sou sifas la

Gray rouye (oksid zenk): gri-blan kouch dans, se kouch zenk ekspoze apre eswiyan

Wouj rouye (oksid fè): mawon-wouj rouye parèt, ak kouch nan zenk te Penetration nan substrate la

Kouch zenk kap dekale koupe: ekaye koupe, ekspoze matris la asye

Galvanized Steel

2. Ki pwen fèb yo nan kouch galvanised ki gen tandans fè korozyon?

Jwenti soude ak zòn ki afekte chalè (tanperati ki lakòz kouch nan zenk yo vin mens);
Kwen ak twou vid ki genyen nan konpozan (dlo/akimilasyon pousyè fasil fòme selil galvanik);
Jwenti boulon (estrès mekanik ki lakòz fann kouch la);
Zòn kache tankou antere l '/anba dlo (pi grav anviwònman korozyon) .

 

3. Ki zouti tès yo ak estanda yo?

Kalib epesè mayetik: Detèmine epesè nan kouch zenk pa mezire chanjman ki fèt nan flux mayetik;
Presizyon: ± 1μm (aplikab a 1-200 μm kouch zenk);
Tès destriktif: Metòd nidite: fonn kouch zenk la ak reyaktif chimik yo, peze ak kalkile epesè a;
Metòd mikwoskòp: Obsève epesè kouch zenk la apre polisaj seksyon an, presizyon ± 2μm .

Galvanized Steel

4. Ki pwen kle pou jije senaryo espesyal yo?

Buried galvanized steel (cooperative judgment of cathodic protection) • Potential detection: Use copper/copper sulfate reference electrode, when the potential is >-0.85V (CSE), the zinc layer is in the state of anodic protection; if the potential is >100mV, it is necessary to check whether the anode block is invalid. • Soil resistivity: When >50Ω ・ M, se pousantaj la korozyon redwi, men galvanik korozyon ka rive (anod sakrifis obligatwa) .
Underwater galvanized steel (coating integrity judgment) • Visual inspection by divers: Focus on whether the coating at the weld and bolt is bubbling (bubble diameter >5mm bezwen repare); • Mezi epesè ultrasons: Detekte yon fwa chak 2 zan nan zòn ki pi wo a 5 mèt anba dlo, ak yon fwa chak ane nan zòn ki anba a 5 mèt (ewozyon koule dlo akselere korozyon) .

Galvanized Steel

5. Ki teknoloji deteksyon émergentes yo?

Enfrawouj tèmik D ': pati ki domaje nan kouch nan zenk disipe chalè byen vit, epi yo ka risk pou korozyon ka idantifye nan diferans tanperati (presizyon ± 0.5 degre);
Lazè pwovoke spèktroskopi pann (LIBS): analiz nan-situ nan konpozisyon an kouch zenk, lè kontni an aliminyòm se mwens pase 5%, rezistans a korozyon diminye ak atansyon yo ta dwe peye;
UAV + AI enspeksyon vizyèl: enspeksyon otomatik ki fonksyone nan eleman wo-altitid (tankou gwo fò tou won transmisyon) ak yon presizyon idantifikasyon nan 0 . 5mm.